North Star M165957K Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Générateurs d'électricité North Star M165957K. North Star M165957K User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 41
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
M165957K
Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Gasoline Generator
6600 Watt Continuous (8000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a
back-up connection to a building’s power supply (via a professionally installed UL-approved
transfer switch.
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up,
operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These
spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly
grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST
ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed
electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so
engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7’ from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station – use
approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator to
your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
ITEM NUMBER: 165957
SERIAL NUMBER: _____________
TM
Vue de la page 0
1 2 3 4 5 6 ... 40 41

Résumé du contenu

Page 1 - M165957K

M165957K Owner’s Manual Instructions for Installation/Set-up, Operation, Servicing, & Storage Portable, Outdoor Use-Only, Gasoline Generator

Page 2

Power Load Planning & Management 10 WARNING NEVER exceed the rated wattage capacity of you

Page 3 - Table of Contents

Power Load Planning & Management (cont’d) 11 Device Running Watts Device Running Watts Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/

Page 4 - WARNING

Installation / Initial Set-Up 12 There are a number of important steps required to set up your gen

Page 5 - ATTENTION:

Installation / Initial Set-Up 13 3. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source This generator is designed to provide up to 8000

Page 6 - SPECIFICATIONS

Installation / Initial Set-Up 14Please read your owner's manual before operating, if you do not havea manual or have questions, call customer

Page 7 - On-Product Warning Labels

Installation / Initial Set-Up 15♦ Extension cords may be used to power devices that are located at a distance from the generator. However, use o

Page 8

Installation / Initial Set-Up 16 4. Select a Suitable Site Before using the generator, you must select a suitable OUTDOOR location for installatio

Page 9 - REFERENCE GUIDE

Installation / Initial Set-Up 17• Situate so there is adequate clearance around generator to allow for cooling airflow so that heat does not buil

Page 10 - WARNING

Installation / Initial Set-Up 18 5. Grounding the generator Always ensure the generator is properly grounded to prevent electrical shock. You must

Page 11

Installation / Initial Set-Up 19 6. Battery Installation Your generator’s engine is equipped with an electric starter which requires the install

Page 12 - 2. Planning the Power Load

Hazard Signal Word Definitions 2

Page 13

Operation 20 Once you have set up your generator for use, it is time to start your generator. T

Page 14 - GROUNDING POST

Operation (cont’d) 21• Malfunction during operation. Immediately turn off the generator if any of the following conditions arise during operatio

Page 15 - Table 2

Operation (cont’d) 22Static electricity and filling the gasoline tank: Static electricity can initiate from ungrounded gasoline tanks or container

Page 16 - WARNING:

Operation (cont’d) 23 2. Preparing for Operation Position generator Position generator in accordance with the instructions given in “Installation

Page 17 - WARNING:

Operation (cont’d) 24 WARNING: Gasoline fire/explosion hazard Gasoline is highly flammable and explosive. Heat, sparks, and flames can ig

Page 18 - 5. Grounding the generator

Operation (cont’d) 25ground to be filled. • Keep nozzle in contact with portable container while filling. Manually control the flow of gasoli

Page 19 - 6. Battery Installation

Operation (cont’d) 26 3. Starting the Engine After you have completed the pre-start checklist procedures, you are ready to start the engine. To

Page 20 - Operation

Operation (cont’d) 27 4. Checking Generator Output Although the speed of the engine was carefully adjusted at the factory so that the generator p

Page 21 - Operation (cont’d)

Operation (cont’d) 28 5. Connecting Loads You will want to be careful when connecting loads so as not to overload the generator, especially if yo

Page 22

Operation (cont’d) 29 7. Storage & Exercise When you are finished using the generator, you must: o Disconnect all loads o Shut off fuel su

Page 23

Table of Contents 3 Hazard Signal Word Definitions ...

Page 24

Operation (cont’d) 30Prepare engine for long term storage if needed If you will not be able to exercise the generator regularly, you must prepare

Page 25

Maintenance & Repair 31 Inspect and maintain your generator as specified below in order to ke

Page 26 - 3. Starting the Engine

Maintenance & Repair (cont’d) 32Check GFCI (if equipped) Once a month, test the Ground Fault Circuit Interrupter (GFCI) to protect against el

Page 27

Troubleshooting 33 TROUBLESHOOTING Problem Possible Causes Possible Remedies Engine

Page 28

Summary of Important Safety Information for Operation 34 This section provides a summary of the v

Page 29 - Storage & Exercise

Summary of Important Safety Information for Operation (cont’d) 35 Installation / Initial Set-up Safety • Dry, level surface. Situate generator

Page 30

Summary of Important Safety Information for Operation (cont’d) 36 Gasoline Safety Gasoline is highly flammable and explosive. You can be burned o

Page 31 - Maintenance & Repair

Summary of Important Safety Information for Operation (cont’d) 37• Avoid contact. Avoid contact with bare wires, terminals, connections, etc. wh

Page 32

Generator Exploded View Rev - K 38

Page 33 - TROUBLESHOOTING

Generator Exploded View Rev - K 39 Ref # Part # Description Qty 1 38759 Fuel Tank Assembly

Page 34 - General

About Your Generator 4 Thank you for purchasing your NorthStar portable generator! About Your Ge

Page 35 - Safety – Before Use

Wiring Diagram Rev - K 40 Diag # Part # Description Qty1 306438 15 Amp, 120 Volt Receptacle (

Page 36 - Safety – During Use

Generator Head Exploded View Rev - K 41 Item # Part # Description

Page 37 - Safety – After use

About Your Generator (cont’d) 5 NorthStar is constantly improving its products. The specifications outlined herein are subject to change without

Page 38

Specifications – Item #165957K 6 SPECIFICATIONS Item Number #165957 Maximum Output 8000 Watts

Page 39

Safety Label Locations – Item #165957K 7 Always make sure safety la

Page 40 - Wiring Diagram Rev - K

Machine Component Identification - Item #165957K 8 Figure 1

Page 41

Machine Component Identification - Item #165957K 9 REFERENCE GUIDE Reference 1 – Circuit Breakers

Commentaires sur ces manuels